Skip to main content
DrywallPlanner

Drywall Thickness Chart and Guide

5 min read

Checked against the primary references linked below.

How thick is drywall? Most interior drywall is 1/2 in (12.7 mm) thick, and ceilings, garages and fire-rated walls often use 5/8 in (15.9 mm). USG makes its regular panels in four thicknesses, 1/4, 3/8, 1/2 and 5/8 in, and specialty fire-rated board goes up to 3/4 in. Picking the wrong one is one of the few drywall mistakes you cannot fix with more compound: half inch board on 24 in ceiling joists under a wet texture is prone to sag, and board that is too thin for a fire rating will not pass inspection. This guide gives a thickness chart with weights and typical uses, then covers ceilings, fire ratings and what thickness changes in your estimate.

1/2 vs 5/8 Drywall

Full page

Room dimensions

Room shape
Length
ft
in
Width
ft
in
Wall height
ft
in

Surfaces & board

Sheet size
1/2 in board
5/8 in board

Your prices

$
From your supplier
$
From your supplier

1/2 in vs 5/8 in for this room

21 sheets of 4' x 8' either way, priced at $15.00 and $19.00 a sheet
+$84.00for 5/8 in board
27% more
Per room1/2 in5/8 in
Board cost$315$399
Weight per sheet51 lb70 lb
Total weight1,075 lb1,478 lb
Screw to buy (USG)1-1/4 in1-1/4 in
GA-216 minimum1-1/8 in1-1/4 in
Fire ratedNoType X

Weights are USG's published lb per sq ft. Sheet counts include 10% waste. Screw counts are the same for both thicknesses: USG recommends 1-1/4 in Type W screws for 1/2 in and 5/8 in board on wood, above the GA-216 minimum shown.

Drywall thickness chart

Millimeters are Georgia-Pacific's nominal metric sizes. Weights are for one 4x8 sheet, from USG's published pounds per square foot, and the uses follow USG's installation guide and IRC Table R702.3.5.

  • 1/4 in (6.4 mm), about 38 lb: a resurfacing board. USG says it should not be applied as a single layer, only over existing walls and ceilings. It is also used to form gentle curves.
  • 3/8 in (9.5 mm), about 45 lb: repairs in older houses that were built with it, and double-layer work. On ceilings USG limits it to framing 16 in on center with the board run across the framing, and does not recommend it below unheated spaces or under a water-based texture.
  • 1/2 in (12.7 mm), about 51 lb regular or 40 lb lightweight: the standard for interior walls, and for ceilings framed 16 in on center, or 24 in with the board run across the framing. Georgia-Pacific lists its lightweight 1/2 in board 48 or 54 in wide and 8 to 16 ft long.
  • 5/8 in (15.9 mm), about 70 lb as type X or 58 lb as lightweight type X: ceilings at 24 in framing under a wet texture, sound control, and fire-rated assemblies. The 2024 IRC calls for 5/8 in type X on a garage ceiling with living space above.
  • 3/4 in (19.1 mm), about 90 lb: a specialty fire-rated panel rather than a general-purpose board. USG makes its Mold Tough Ultracode Core panels 3/4 in thick as type X, 4 ft wide and 8 to 12 ft long, for fire-rated walls and ceilings where fewer layers save space.

Weight follows thickness and drives how the job runs: a 4x12 sheet of 5/8 in type X is about 106 lb. Lightweight 1/2 in board, at 1.25 lb per sq ft against 1.6 for regular, is about a fifth lighter, which is a real help on ceilings. Every thickness carries a small tolerance; Georgia-Pacific lists its board at plus or minus 1/64 in of the nominal thickness.

Ceiling drywall thickness

A ceiling carries its own weight in bending between the joists, and gypsum creeps slowly under sustained load. That is why a ceiling that looked flat on day one can show a gentle wave two summers later. The fix is a stiffer board or closer framing; extra screws do nothing for it.

  • Joists at 16 in on center: 1/2 in board is acceptable. Half inch sag resistant board is better and costs little more.
  • Joists at 24 in on center: IRC Table R702.3.5 allows 1/2 in board installed perpendicular to the joists, within the table limit on the weight of insulation above it, but 5/8 in or 1/2 in sag resistant board is the better choice, and one of the two is required under a water-based spray or hand texture.
  • Anywhere you will spray a heavy texture: go thicker. Wet texture adds load before it cures, which is exactly when the board is weakest.
  • Under a bathroom or laundry above: 5/8 in also buys you useful sound reduction.

Sag resistant board is not the same as standard board. It has a denser core formulated for spans and is sold under names like sag resistant or ceiling board. Check the label rather than the aisle.

Fire ratings and where code has an opinion

Type X board commonly uses a 5/8 in fire-resistant core with reinforcing glass fibers. It is one component of many tested fire-rated assemblies, but the board alone does not create a rating. Type C is used when a specific listed assembly calls for it.

  • Under the 2024 IRC model code, the garage side adjoining a dwelling or attic uses at least 1/2 in gypsum board, while a garage ceiling below the dwelling uses at least 5/8 in type X or equivalent. Your adopted local code controls.
  • Walls between attached dwelling units, and around some furnaces and utility rooms, are commonly rated assemblies.
  • A rated assembly is the whole build-up, of which the board is one part. Fastener spacing, joint treatment and even the screw type are part of the listing.
  • Doubling half inch board does not produce a one hour rating. Rated assemblies are tested combinations and cannot be added up.

If a permit is involved, get the required assembly from your building department before you order. Board is cheap; taking a ceiling down because the inspector wanted type X is not.

Does thickness change your estimate?

Not the sheet count. Board is sold by the sheet at a fixed 4 ft width, so a 4x8 sheet is 32 sq ft whether it is half inch or five eighths. Our calculator counts sheets, so it works identically for any thickness.

Thickness changes three other things: the price per sheet, the weight you have to carry, and the screw length you need. Budget very roughly 30% to 50% more per sheet for five eighths type X than for standard half inch (prices vary by region and supplier), check screw length (USG recommends 1-1/4 in Type W screws for both thicknesses, GA-216 minimum 1-1/8 / 1-1/4 in, though many crews use 1-5/8 in for five eighths), and plan on two people or a lift for the heavier board.

One more practical point: do not mix thicknesses on the same plane. A half inch sheet meeting a five eighths sheet leaves a 1/8 in step that no amount of feathering fully hides.

Drywall Ceiling Calculator

Ceiling-only estimate with the right screw density applied.

Open calculator

Frequently asked questions

How thick is drywall?

Most interior drywall is 1/2 in thick, or 12.7 mm. The other common thicknesses are 1/4 in (6.4 mm) for resurfacing, 3/8 in (9.5 mm) for repairs and double layers, and 5/8 in (15.9 mm) for ceilings and fire-rated walls.

What thickness sheetrock is used for walls?

Half inch, in most houses. Sheetrock is USG's brand name for its gypsum panels, and the same thicknesses apply to any brand. Use 5/8 in type X where a fire-rated wall calls for it. Three eighths inch board turns up in older houses, and quarter inch is only a resurfacing or curved-wall material.

Is 1/2 in or 5/8 in drywall better for ceilings?

At 16 in joist spacing half inch is acceptable. At 24 in, IRC Table R702.3.5 still allows half inch run perpendicular to the joists, but five eighths or half inch sag resistant board is the safer choice, and one of them is required under a water-based texture. Sag resistant half inch weighs noticeably less than five eighths.

Is there 3/4 inch drywall?

Yes, as a specialty fire-rated board. USG makes its Mold Tough Ultracode Core panels 3/4 in thick as type X, 4 ft wide and 8 to 12 ft long, at a nominal 2.8 lb per sq ft, about 90 lb for a 4x8 sheet. They are meant for fire-rated assemblies that would otherwise need more layers. For ordinary walls and ceilings 5/8 in is the thickest board you need, and it is about 20 lb lighter per 4x8 sheet.

Do I need type X drywall in my garage?

It depends on the surface and your adopted code. The 2024 IRC model code calls for at least 1/2 in gypsum board on the garage side adjoining a dwelling or attic, and at least 5/8 in type X or equivalent below the dwelling. Confirm the local requirement before ordering.

How much does a sheet of drywall weigh?

About 51 lb for a 4x8 sheet of half inch, 77 lb for a 4x12 of half inch, and about 106 lb for a 4x12 of five eighths type X, by USG's published weights. Lightweight half inch board runs about a fifth lighter than standard.

Can I use 1/4 in drywall on a wall?

Only as a skin over an existing sound wall, or to form a gentle curve. It has no useful strength on open framing and will not meet any fire or impact requirement on its own.

Primary references

IRC Table R702.3.5 and R302.6 set where each thickness is required, and the USG and Georgia-Pacific product sheets give the sizes, weights and properties of each board.