Drywall Thickness Chart and Guide
How thick is drywall? Most interior drywall is 1/2 in (12.7 mm) thick, and ceilings, garages and fire-rated walls often use 5/8 in (15.9 mm). USG makes its regular panels in four thicknesses, 1/4, 3/8, 1/2 and 5/8 in, and specialty fire-rated board goes up to 3/4 in. Picking the wrong one is one of the few drywall mistakes you cannot fix with more compound: half inch board on 24 in ceiling joists under a wet texture is prone to sag, and board that is too thin for a fire rating will not pass inspection. This guide gives a thickness chart with weights and typical uses, then covers ceilings, fire ratings and what thickness changes in your estimate.
1/2 vs 5/8 Drywall
Full page1/2 in vs 5/8 in for this room
21 sheets of 4' x 8' either way, priced at $15.00 and $19.00 a sheet27% more
| Per room | 1/2 in | 5/8 in |
|---|---|---|
| Board cost | $315 | $399 |
| Weight per sheet | 51 lb | 70 lb |
| Total weight | 1,075 lb | 1,478 lb |
| Screw to buy (USG) | 1-1/4 in | 1-1/4 in |
| GA-216 minimum | 1-1/8 in | 1-1/4 in |
| Fire rated | No | Type X |
Weights are USG's published lb per sq ft. Sheet counts include 10% waste. Screw counts are the same for both thicknesses: USG recommends 1-1/4 in Type W screws for 1/2 in and 5/8 in board on wood, above the GA-216 minimum shown.
Drywall thickness chart
Millimeters are Georgia-Pacific's nominal metric sizes. Weights are for one 4x8 sheet, from USG's published pounds per square foot, and the uses follow USG's installation guide and IRC Table R702.3.5.
- 1/4 in (6.4 mm), about 38 lb: a resurfacing board. USG says it should not be applied as a single layer, only over existing walls and ceilings. It is also used to form gentle curves.
- 3/8 in (9.5 mm), about 45 lb: repairs in older houses that were built with it, and double-layer work. On ceilings USG limits it to framing 16 in on center with the board run across the framing, and does not recommend it below unheated spaces or under a water-based texture.
- 1/2 in (12.7 mm), about 51 lb regular or 40 lb lightweight: the standard for interior walls, and for ceilings framed 16 in on center, or 24 in with the board run across the framing. Georgia-Pacific lists its lightweight 1/2 in board 48 or 54 in wide and 8 to 16 ft long.
- 5/8 in (15.9 mm), about 70 lb as type X or 58 lb as lightweight type X: ceilings at 24 in framing under a wet texture, sound control, and fire-rated assemblies. The 2024 IRC calls for 5/8 in type X on a garage ceiling with living space above.
- 3/4 in (19.1 mm), about 90 lb: a specialty fire-rated panel rather than a general-purpose board. USG makes its Mold Tough Ultracode Core panels 3/4 in thick as type X, 4 ft wide and 8 to 12 ft long, for fire-rated walls and ceilings where fewer layers save space.
Weight follows thickness and drives how the job runs: a 4x12 sheet of 5/8 in type X is about 106 lb. Lightweight 1/2 in board, at 1.25 lb per sq ft against 1.6 for regular, is about a fifth lighter, which is a real help on ceilings. Every thickness carries a small tolerance; Georgia-Pacific lists its board at plus or minus 1/64 in of the nominal thickness.
Ceiling drywall thickness
A ceiling carries its own weight in bending between the joists, and gypsum creeps slowly under sustained load. That is why a ceiling that looked flat on day one can show a gentle wave two summers later. The fix is a stiffer board or closer framing; extra screws do nothing for it.
- Joists at 16 in on center: 1/2 in board is acceptable. Half inch sag resistant board is better and costs little more.
- Joists at 24 in on center: IRC Table R702.3.5 allows 1/2 in board installed perpendicular to the joists, within the table limit on the weight of insulation above it, but 5/8 in or 1/2 in sag resistant board is the better choice, and one of the two is required under a water-based spray or hand texture.
- Anywhere you will spray a heavy texture: go thicker. Wet texture adds load before it cures, which is exactly when the board is weakest.
- Under a bathroom or laundry above: 5/8 in also buys you useful sound reduction.
Sag resistant board is not the same as standard board. It has a denser core formulated for spans and is sold under names like sag resistant or ceiling board. Check the label rather than the aisle.
Fire ratings and where code has an opinion
Type X board commonly uses a 5/8 in fire-resistant core with reinforcing glass fibers. It is one component of many tested fire-rated assemblies, but the board alone does not create a rating. Type C is used when a specific listed assembly calls for it.
- Under the 2024 IRC model code, the garage side adjoining a dwelling or attic uses at least 1/2 in gypsum board, while a garage ceiling below the dwelling uses at least 5/8 in type X or equivalent. Your adopted local code controls.
- Walls between attached dwelling units, and around some furnaces and utility rooms, are commonly rated assemblies.
- A rated assembly is the whole build-up, of which the board is one part. Fastener spacing, joint treatment and even the screw type are part of the listing.
- Doubling half inch board does not produce a one hour rating. Rated assemblies are tested combinations and cannot be added up.
If a permit is involved, get the required assembly from your building department before you order. Board is cheap; taking a ceiling down because the inspector wanted type X is not.
Does thickness change your estimate?
Not the sheet count. Board is sold by the sheet at a fixed 4 ft width, so a 4x8 sheet is 32 sq ft whether it is half inch or five eighths. Our calculator counts sheets, so it works identically for any thickness.
Thickness changes three other things: the price per sheet, the weight you have to carry, and the screw length you need. Budget very roughly 30% to 50% more per sheet for five eighths type X than for standard half inch (prices vary by region and supplier), check screw length (USG recommends 1-1/4 in Type W screws for both thicknesses, GA-216 minimum 1-1/8 / 1-1/4 in, though many crews use 1-5/8 in for five eighths), and plan on two people or a lift for the heavier board.
One more practical point: do not mix thicknesses on the same plane. A half inch sheet meeting a five eighths sheet leaves a 1/8 in step that no amount of feathering fully hides.
Drywall Ceiling Calculator
Ceiling-only estimate with the right screw density applied.
Frequently asked questions
How thick is drywall?
What thickness sheetrock is used for walls?
Is 1/2 in or 5/8 in drywall better for ceilings?
Is there 3/4 inch drywall?
Do I need type X drywall in my garage?
How much does a sheet of drywall weigh?
Can I use 1/4 in drywall on a wall?
Primary references
IRC Table R702.3.5 and R302.6 set where each thickness is required, and the USG and Georgia-Pacific product sheets give the sizes, weights and properties of each board.
- Sheetrock Brand Gypsum PanelsUSG
- Sheetrock Brand Installation and Finishing GuideUSG
- 2024 IRC Table R702.3.5, gypsum board thickness and applicationInternational Code Council
- 2024 IRC Section R302.6, dwelling and garage separationInternational Code Council
- Sheetrock Brand gypsum panels submittal, weights by thickness (WB1473)USG
- USG wallboard portfolio, panel weights (WB2816)USG
- ToughRock technical guide, gypsum board physical propertiesGeorgia-Pacific
- Sheetrock Brand Mold Tough Ultracode Core Panels, 3/4 in type X, product documentationUSG